Overview

A shipment of 17414 printed circuit boards that were less than the lower limit for thickness was received and entered into production of SR receiver interconnect adapters, which revealed a problem with some models of the adapters.
The problem is that the connector on the adapter does not mate reliably with the connector in the receiver. A poor mating connection can result in an intermittent or non-existent power connection whereby the unit will not power up or will inadvertently lose power.

Adapters that need to be exchanged

The battery sled models in the customer’s hands that are exhibiting this problem should be returned to the factory to be replaced.

  • SRBATTSLED Top Version
  • SRBATTSLED Bottom Version

The SREXT model does not exhibit this problem, and as such, is not listed in this bulletin.

Adapters that can be updated in the field

The following models may be returned for exchange at the factory, or the problem can easily be resolved in the field by installing the appropriate shim between the circuit board assembly and the panel, using slightly longer screws with the SRUNI and SRSNY.

  • SRUNI
  • SRSNY
  • SRHARNESS

Part numbers and instructions for the update of these three models are included in this bulletin.

SRUNI Update

Placing a shim under the PCB and re-assembling the unit with longer screws takes care of the problem.

SB1006 SR adapter shims and screws: P/N 26871 shim, P/N 26845 screws

Placing a shim under the PCB and re-assembling the unit with longer screws takes care of the problem.

SB1006 SR adapter: Remove and discard spare screws before installing shims.

Orient the shim to match the opening in the panel. Align the holes and press the shim into the recess in the panel.

SB1006 SR adapter shim installation: metal shims and screws

Re-assemble with the longer screws.

Lectrosonics SR adapter installation: screwing in a shim for the SB1006 update.

SRSNY Update

Placing a shim under the PCB and re-assembling the unit with longer screws takes care of the problem. The update involves two parts.

SB1006 SR Adapter update: screws P/N 28645 and shim P/N 28670

Remove the original screws and separate the connector and PCB assembly. Discard the screws.

SR Adapter update: Remove and discard screws for shims installation

Orient the shim to match the opening in the panel. Align the holes and press the shim into the recess in the panel.

SB1006 SR adapter shims and screws

Re-assemble with the longer screws.

Installing SB1006 SR Adapter shims with a screwdriver.

SRHARNESS Update

The update to this adapter involves the installation of two nylon washers.

Nylon washers P/N 28893, .020" thick, for SR adapter update

The washers are installed between the circuit board and panel to prevent warping the circuit board when the screws are tightened.

Spacer washers on SR adapter circuit board for SB1006 SR adapter update.

First remove the two screws that retain the circuit board.

SR adapter update: Remove screws from PCB for shims installation.

Insert the washers between the circuit board and mounting tabs on the panel. Gently apply pressure to the circuit board to pull it slightly away from the tabs to allow room for the washers to be inerted. A tool such as a small screwdriver can be used to move the washers into place.

Slide washers between circuit board and panel mounts for SR adapter update.

After the tabs are in place, hold gentle pressure on the circuit board to keep the washers from moving. Then turn the assembly over and align the holes in the washers with the holes in the circuit board and threaded holes in the mounting tabs. A small, pointed tool with a dull tip such as a paper clip can be used to reach through the hole and make adjustments to the washer location. Gently move the circuit board with your fingers to align the holes with the threaded holes in the panel.

Aligning SR adapter shims on circuit board with paperclip tool for SB1006 update.

Replace the screws and tighten them snugly. Be careful not to overtighten them.

Close-up of SRHARNESS circuit board with two screws circled for SB1006 SR Adapter update